Effect of pH and VFA on hydrolysis of organic solid wasteстатья
Статья опубликована в высокорейтинговом журнале
Информация о цитировании статьи получена из
Web of Science,
Scopus
Статья опубликована в журнале из списка Web of Science и/или Scopus
Дата последнего поиска статьи во внешних источниках: 18 июля 2013 г.
Аннотация:The anaerobic hydrolysis rate of organic solid waste was studied at fixed volatile fatty acid (VFA) concentrations ranging from 3 to 30 g COD/L and fixed pH values between 5 and 7. For separate control of both VFA and pH, a special completely mixed reactor was designed. In this way, it was possible to distinguish between the inhibitory effects of pH, total VFA, and undissociated VFA on anaerobic hydrolysis. It was shown that hydrolysis of the organic solid waste followed first-order kinetics. Using a statistical analysis, it was found that the hydrolysis rate constant was pH dependent but was not related to total VFA and undissociated VFA concentrations. The anaerobic hydrolysis rate of organic solid waste was studied at fixed volatile fatty acid (VFA) concentrations ranging from 3 to 30 g COD/L and fixed pH values between 5 and 7. For separate control of both VFA and pH, a special completely mixed reactor was designed. In this way, it was possible to distinguish between the inhibitory effects of pH, total VFA, and undissociated VFA on anaerobic hydrolysis. It was shown that hydrolysis of the organic solid waste followed first-order kinetics. Using a statistical analysis, it was found that the hydrolysis rate constant was pH dependent but was not related to the total VFA and undissociated VFA concentrations.