Optimization of electromagnetic diagnostic system of the T-15 tokamakстатья

Дата последнего поиска статьи во внешних источниках: 24 марта 2017 г.

Работа с статьей


[1] Optimization of electromagnetic diagnostic system of the t-15 tokamak / I. V. Zotov, A. V. Melnikov, D. Y. Sychugov et al. // 43 EPS Conference on Plasma Physics, Leuven, Belgium, 4-8 July 2016. — Vol. 40 of Europhysics Conference Abstracts (ECA) series F. — Switzerland: Switzerland, 2016. — P. P2.035. The modernization of the T-15 tokamak requires a detailed study of electromagnetic diagnostic system [1]. The minimum required number of probes used to determine the boundary of the plasma with a given accuracy is in operation. Measurement error is taken as the calculation parameter and varies in the range from 0 to 3%. The analysis is conducted on the basis of one of the possible discharge scenarios in the T-15 upgrade tokamak, calculated using TOKSCEN and DINA numerical modules taken from the Virtual Tokamak codes library (plasma-fusion.ru). The current increase stage is analyzed partially and stationary discharge stage (total current of 1.4 to 2 MA) is analyzed at full measure. Recovery of the plasma boundary is performed using the RPB (Reconstruction of Plasma Boundary) code [2] under the condition that the probes location is on the first wall of the vacuum chamber.

Публикация в формате сохранить в файл сохранить в файл сохранить в файл сохранить в файл сохранить в файл сохранить в файл скрыть