Аннотация:Spaghetti-type calorimeters (SpaCal) are being considered as a potential solution for experiments at the High-Luminosity Large Hadron Collider (HL-LHC), particularly for the LHCb ECAL Upgrade 2 project where the expected instantaneous intensity and radiation dose in the central area of the ECAL significantly exceed the limits tolerable by the current Shashlik-type modules.SpaCal modules consist of an absorber block containing a matrix of holes filled with scintillating fibres, offering flexible granularity. However, the total number of scintillating fibres exceeds the available photocathode surface area, necessitating the use of a light guide to efficiently collect and register the light from the scintillating fibres to a single photomultiplier. This introduces non-uniformity in the light collection, which adversely impacts energy resolution.In this study, we explored various geometries of light guides with the optical ray-tracing simulations in order to collect scintillating light from a $30\times 30$~mm$^2$ surface to the photocathode of photomultipliers with the following entrance window: $18\times 18$~mm$^2$ (e.g. R7600), $9\times 9$~mm$^2$ (multi-anode version, e.g. R7600-M4), and round photocathode $\oslash 8$~mm (e.g. R9880). The light collection non-uniformity impact on the energy resolution is estimated.